2015849.1
:
FS System: Deleting Auto-Tier LUNs May Not Increase Free Space for a Storage Domain
Related Items |
- Oracle FS1-2 Flash Storage System
|
Related Categories |
- PLA-Support>Sun Systems>DISK>Flash Storage>SN-EStor: FSx
|
In this Document
Created from <SR 3-10742434334>
Applies to:
Oracle FS1-2 Flash Storage System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
After deleting Auto-Tier LUNs the user may not see an increase in free space for a Storage Domain seen from the GUI.
Cause
When deleting Auto-Tier LUNs space may not be freed automatically by the FS1-2 as the space will be available for other Auto-Tier LUNs to use in the Storage Domain.
Solution
Within a Storage Tier, if the total space allocated for Auto-Tier LUNs is at 20% utilization or less, then the Storage Domain will do an automatic compaction to free some of the space. If the total space allocated for Auto-Tier LUNs within a storage tier is greater than 20% utilization, then a manual Storage Domain compaction can be forced to free space.
To force a manual storage domain compaction:
- Log into the FS1-2 GUI and navigate to the "System" tab.
- In the navigation tree, click "Storage Domains".
- On the main page select the appropriate Storage Domain.
- Either right mouse click or from the Menu bar, select "Actions" and then select "Compact Storage Domain".
- In the "Tasks" window there will be a PerfromDefragmentation background process running, once the process reaches 100% or disappears check the increase in available free space.
References
<BUG:21094150> - FS1 HAS NOT RELEASE SPACE FROM DELETED LUNS