Solution Type Problem Resolution Sure Solution 2014094.1 : SL150 - Tape Library Is Showing Robot Failure Error
In this Document
Created from <SR 3-10614118952> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions and laterInformation in this document applies to any platform. SymptomsTape Library Is Showing Robot Failure Error. Equipment Inoperable State, Fault Code 9104, 9114 CauseThe problem was a bent retaining clip on the base module such that the robot could not pass to inventory the Drive Expansion Module. Some mis-allignment on the base module we had to replace it entirely. SolutionReplaced the base module. Applies to:References<NOTE:1917365.1> - SL150 - Error Message / Module Count is Greater than Z Range for Modules Calculation: MCI ModCnt<NOTE:1285688.1> - How to Order Parts Using the 'No Parts Process', NOPRT <NOTE:1929585.1> - SL150 - Equipment Inoperable State, Fault Code 9104, 9114 <NOTE:1910640.1> - SL150 - New Installation, Robot Initialization Failure Code 9109 <NOTE:1473774.1> - SL150 - How to Remove/Replace the Robot CRU in a StorageTek SL150 Modular Tape Library:ATR:1473774.1:0 Attachments This solution has no attachment |
||||||||||||||||||||
|