Symptoms
Changes
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Requires experience field engineer to replace HBV and possibly L753---L324 cable assembly
Created from <SR 3-10776846688>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Symptoms:

- CAP icon Red.
- No elevators or SSD configured into the device tree.
- No active HBZ module LED.
- PS_25 & 26 had active green LEDs.
- HBZ bond_0 down.

Found:

-No boot up sequence noted on HBZ card via connector J100 at 38.4 8/N/1
-No 48vs on pin_1 or pin_2 on P753----PJ324_HBV

Log snapshot - HBC log:

    2015-05-20T13:19:13.470 error 1.0.0.0.0 6005 "Bond state DOWN - Board : hbza, iface : bond0 (Internal LAN)"     BondMonitor root default 0
    2015-05-20T13:19:13.479 warn 1.0.0.0.0 6004 "Link state DOWN - Board : hbza, iface : eth0 (HBZ1A)"     BondMonitor root default 0
    2015-05-20T13:19:13.488 error 1.0.0.0.0 6005 "Bond state DOWN - Board : hbzb, iface : bond0 (Internal LAN)"     BondMonitor root default 0
    2015-05-20T13:19:13.497 warn 1.0.0.0.0 6004 "Link state DOWN - Board : hbzb, iface : eth0 (HBZ2A)"     BondMonitor root default 0
    2015-05-20T13:19:16.763 trace 1.0.0.0.0 6002 "Failed to create tmp copy of Procfs bond info file for remote board hbza"     BondMonitor root default 0

Changes

 SL8500 - adding expansion module.

Cause

Local support Ohm'd out fuse F200 and found it open due to short on cable P753---P324 going from HBV to Knuckle cable.

Refer to following pictures for clarity.


 

Solution

Replace HBV -

314808901 [F] HBV Card, Customer Interface Module Power Supply Interface, PWA