Solution Type Problem Resolution Sure Solution 2007359.1 : SL8500 - Download File Write Failed, FSC 3405
Various library component failures that cause an attempted code load can generate the error "3405 - 0000 Download file write failed : retrying with DCI, Exception=scp command failed SCP command gave bad exit value" In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. Component code load attempted SymptomsSun StorageTek SL-series Modular Library System 3405 - 0000 Download file write failed : retrying with DCI, Exception=scp command failed SCP command gave bad exit value. A component in the library has failed and attempted a code load. ChangesNone CauseComponent failures that attempt to perform a code load see the code load fail as a result of the failed component. This generates the file download failure messaging The failed component could be the robot, a ptp, an elevator, or any device within the library that has failed, and attempted to perform a code load. SolutionReview the log snapshot output to identify what device has failure messages and corresponding code load failures during the same timeframe. FE onsite visit required to inspect, reboot, and if necessary replace the failed component. Attachments This solution has no attachment |
||||||||||||||||||
|