Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2007359.1
Update Date:2017-09-11
Keywords:

Solution Type  Problem Resolution Sure

Solution  2007359.1 :   SL8500 - Download File Write Failed, FSC 3405  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: Remote
  •  


Various library component failures that cause an attempted code load can generate the error "3405 - 0000 Download file write failed : retrying with DCI, Exception=scp command failed  SCP command gave bad exit value"

In this Document
Symptoms
Changes
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Created from <SR 3-10702843221>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Component code load attempted

Symptoms

Sun StorageTek SL-series Modular Library System

FSC(3405): Download file write failed.

3405 - 0000 Download file write failed : retrying with DCI, Exception=scp command failed  SCP command gave bad exit value.

A component in the library has failed and attempted a code load.

Changes

None

Cause

Component failures that attempt to perform a code load see the code load fail as a result of the failed component.  This generates the file download failure messaging  The failed component could be the robot, a ptp, an elevator, or any device within the library that has failed, and attempted to perform a code load.
 

Solution

Review the log snapshot output to identify what device has failure messages and corresponding code load failures during the same timeframe.  FE onsite visit required to inspect, reboot, and if necessary replace the failed component.


Attachments
This solution has no attachment