Solution Type  Problem Resolution Sure

Solution  2007209.1 :   SL8500- Robot Not Announcing Itself Properly to the Library - FSC: 3991 "Error in announce presence Error in announce input"  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  


Apparently the robot 1.2.0.1.0 was not announced properly to the library and the library is not communicating properly to it and that causes communication issues with the ACSLS

In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-10696135201>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Customer states that they have one LSM (0,2) out of 4 that is not operational.  They tried to vary it online, then to reset the LSM, but no change to the issue.

FSC: 3991 Error in announce presence
2015-05-05T08:45:46.871, 1.0.0.0.0, root, default, internal, 0, error, 3991, "Error in announce presence Error in announce input", data=announcePresenceinternalActivitysnmp exception=java.net.SocketException

 

Cause

The robot 1.2.0.1.0 was not announced properly to the library and the library is not communicating properly to it.  This causes communication issues with the ACSLS.

Solution

1. Vary LSM's offline (all of them).
2. Perform a Card Cage reboot. Drop the white circuit breakers on the ECM.. Wait 15 seconds.  Up the ECM breakers and wait 2.5 minutes.  Go around to the front of the library and depress the ERS button ( emergency robotics stop ).  Wait 15 seconds.  Depress the ERS button again to allow the robots to re-announce themselves to the library controller.
3. When the library has completed the reboot vary the LSM's back online.
4. Monitor the library for 100% functionality.
 

References

<NOTE:1481296.1> - SL8500 - How to Bring Back BOTs, Elevators, CAPs That Disappear or Show Red After a Power Cycle of the Card Cage