Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2006340.1
Update Date:2017-09-26
Keywords:

Solution Type  Problem Resolution Sure

Solution  2006340.1 :   ES1-24 Switch - "forward-unreg static-ports extreme-ethernet" added automatically  


Related Items
  • Oracle Switch ES1-24
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Ethernet Switches
  •  
  • Tools>Primary Use>Configuration
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-10661239861>

Applies to:

Oracle Switch ES1-24 - Version All Versions and later
Information in this document applies to any platform.

Symptoms

From the output below, how can I get rid of "forward-unreg static-ports extreme-ethernet 0/1,0/23-24 port-channel 3" from vlan 123?

SEFOS# show run

Building configuration...
!
!
shutdown dcb
spanning-tree mode rst
vlan 1
ports extreme-ethernet 0/12,0/15-18,0/21-24 port-channel 3,2 untagged
extreme-ethernet 0/12,0/15-18,0/21-24 port-channel 3

!
vlan 123
ports extreme-ethernet 0/1 port-channel 3 untagged extreme-ethernet 0/1

forward-unreg static-ports extreme-ethernet 0/1,0/23-24 port-channel 3         <<<<<<==========
!

Changes

The current firmware version running on this ES1-24 switch is:

SEFOS# show system information

Hardware Version                  : 2.5.8_00209384
Firmware Version                  : ES1-24-1.3.1.1     <<<====
Switch Name                       : Oracle ES1-24
System Contact                   :
System Location                  :
Logging Option                     : Console Logging
Login Authentication Mode     : Local
Config Save Status               : Successful
Remote Save Status             : Not Initiated
Config Restore Status           : Successful
 

Cause

This 'forward-unreg static-ports' output is not an error or a warning.

It is just an informative purpose.

 

The " forward-unreg static-ports " setting has been removed in more actual firmware versions.


The

   BUG 15738310 - SUNBT7083943 [CSR 1-8933975] "forward-unreg static-ports" entry shows up after p

can explain the reason, but the solution offered in the above Bug is related to the NEM/TOR product.

 

Solution

The FW version running on the ES-24 is old.

The lines have gone away following firmware upgrade, using the latest FW version ( 1.3.1.7 ) available:

      Patch 17050841: ORACLE SWITCH ES1-24 1.3

 

References

<BUG:15738310> - SUNBT7083943 [CSR 1-8933975] "FORWARD-UNREG STATIC-PORTS" ENTRY SHOWS UP AFTER P

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.