Asset ID: |
1-72-2005374.1 |
Update Date: | 2016-10-05 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2005374.1
:
ELAP DRBD Split Brain
Related Items |
- Oracle Communications EAGLE (Hardware)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS ELAP LSMS
|
In this Document
Created from <SR 3-10664938261>
Applies to:
Oracle Communications EAGLE (Hardware) - Version ELAP 10.0 and later
Information in this document applies to any platform.
Symptoms
Both ELAP A and ELAP B are in Active HA status. drbd is not replicating
Cause
Connectivity from ELAP A to the eagle is consist, however, connectivity to both switches was failing.
Issue was eth11 and eth12 seemed hung on ELAP B and switch1B had fault light.
Solution
Up and down eth11 and eth12. Reset switch1B. Performed init 4 on ELAP B to bring it online. synced drbd between servers. All is well.