Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2005374.1
Update Date:2016-10-05
Keywords:

Solution Type  Problem Resolution Sure

Solution  2005374.1 :   ELAP DRBD Split Brain  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS ELAP LSMS
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-10664938261>

Applies to:

Oracle Communications EAGLE (Hardware) - Version ELAP 10.0 and later
Information in this document applies to any platform.

Symptoms

Both ELAP A and ELAP B are in Active HA status. drbd is not replicating

Cause

Connectivity from ELAP A to the eagle is consist, however, connectivity to both switches was failing.
 
Issue was eth11 and eth12 seemed hung on ELAP B and switch1B had fault light.
 

Solution

Up and down eth11 and eth12. Reset switch1B. Performed init 4 on ELAP B to bring it online. synced drbd between servers. All is well.
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.