![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2003778.1 : Sun SPARC Enterprise Server E3x00/E4x00/E5x00/E6x00 ( SunFire Classic ): Failed Peripheral Power Supply preventing server boot.
In this Document
Applies to:Sun Enterprise 5000 Server - Version All Versions and laterSun Enterprise 5500 Server - Version All Versions and later Sun Enterprise 6000 Server - Version All Versions and later Sun Enterprise 6500 Server - Version All Versions and later Sun Enterprise 3000 Server - Version All Versions and later Information in this document applies to any platform. SymptomsDuring the POST, the server displays the error "Peripherial Power Supply PPSS_0 Failed" or "Overtemp detected on board X". The following system messages indicate environmental conditions: Hardware Power ON
0,0>ERROR: TEST=Environmental Probe,SUBTEST=Environmental Probe ID=1f.1 0,0>Component under test: Board 0 System Interrupt 0,0>No power supply cooling available for Clock Control board 0,0>ERROR: TEST=Environmental Probe,SUBTEST=Environmental Probe ID=1f.1 0,0>Component under test: Board 0 System Interrupt 0,0>Peripherial Power Supply PPSS_0 Failed 0,0>ERROR: TEST=Environmental Probe,SUBTEST=Environmental Probe ID=1f.1 0,0>Component under test: Board 0 System Interrupt 0,0>Peripherial Power Supply PPSS_0 Failed 0,0>ERROR: TEST=System Interrupts,SUBTEST=System Interrupts ID=1f.1 0,0>Component under test: Board 0 System Interrupt 0,0>No power supply cooling available for Clock Control board 0,0>ERROR: TEST=System Interrupts,SUBTEST=System Interrupts ID=1f.1 0,0>Component under test: Board 0 System Interrupt 0,0>Peripherial Power Supply PPSS_0 Failed 0,0>ERROR: TEST=System Interrupts,SUBTEST=System Interrupts ID=1f.1 0,0>Component under test: Board 0 System Interrupt 0,0>Peripherial Power Supply PPSS_0 Failed Clock board TOD does not match TOD on any IO board. screen not found. Clock board TOD does not match TOD on any IO board. 8-slot Sun Enterprise 4000/5000, No Keyboard OpenBoot 3.2.22, 512 MB memory installed, Serial #11323890. Ethernet address 8:0:20:ac:c9:f2, Host ID: 80acc9f2. {0} ok PROM NOTICE: Overtemp detected on board 1 PROM NOTICE: Overtemp detected on board 1 PROM NOTICE: Overtemp detected on board 1
CauseThis errors can be related to
SolutionReplace the Power supply faulted: Peripherial Power Supply with the part number 300-1301 Power Cooling Module with part number 300-1444
References<BUG:14934453> - SUNBT4037342 UE PERIPHERAL POWER SUPPLY FAILURE PREVENTS SYSTEM FROM BOOTINGAttachments This solution has no attachment |
||||||||||||||||||
|