![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 2003562.1 : Exadata and SuperCluster Firmware Verification on InfiniBand Switch xxx -ib1 Failed, Possibly Due to Custom Configuration Changes
Created from <SR 3-10648844838> Applies to:Oracle Exadata Storage Server Software - Version 12.1.2.1.1 to 12.1.2.1.1 [Release 12.1]Sun Datacenter InfiniBand Switch 36 - Version All Versions to All Versions [Release All Releases] SPARC SuperCluster T4-4 - Version All Versions and later Oracle SuperCluster T5-8 Hardware - Version All Versions and later Oracle SuperCluster M6-32 Hardware - Version All Versions and later Information in this document applies to any platform. Symptoms While upgrading the ibswitches you encounter errors during the verification of the installed files
SUCCESS: DO: Initiate upgrade of InfiniBand switches to 2.1.5-1. Expect up to 15 minutes for each switch
Upgrading IB switches from version 2.1.4-1 to 2.1.5-1 fails with the following error: [root@xyzsw-ib3 ~]# fwverify Checking all present packages: .............................................................................. ............................................................. OK Checking if any packages are missing: .............................................................................. ........................................................ OK Verifying installed files: .............................................................................. ........................................................... FAILED * Package tzdata-2012c-1.el5.i386: .M...... /usr/share/zoneinfo/America/Los_Angeles .M...... /usr/share/zoneinfo/US/Pacific Checking FW Coreswitch: FW Version: 7.4.2202 OK PSID: SUN_NM2-36p_004 OK Verifying image integrity OK Closer inspection confirmed that the permissions on the following files on the IB Switch are set to 777 * Package tzdata-2012c-1.el5.i386: .M...... /usr/share/zoneinfo/America/Los_Angeles .M...... /usr/share/zoneinfo/US/Pacific Checking FW Coreswitch: FW Version: 7.4.2202 OK PSID: SUN_NM2-36p_004 OK Verifying image integrity OK Changespatching IBSwitches to 2.1.5-1 CauseBug 20458988 when the permissions are not set as expected when upgrading IB switches to 2.1.5-1 Fails "...I found that the Firmware install fails because the permission of this files is set to 777 ..."
SolutionSwitch permissions for the reported tz files on the switch to 644 Rerun the patch Then the switch firmware upgrade should be successful. References<BUG:20458988> - UPGRADING IB SWITCHES TO 2.1.5-1 FAILSAttachments This solution has no attachment |
||||||||||||
|