Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2002611.1
Update Date:2015-10-14
Keywords:

Solution Type  Problem Resolution Sure

Solution  2002611.1 :   ProPerf Graph is Showing Insufficient Privilege Message  


Related Items
  • Oracle Communications Performance Intelligence Center (PIC) Software
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-10366393131>

Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 7.1 and later
Tekelec
ProPerf graph is updating based on data available in row and column of a statistic session associated with a Xdr session.

Symptoms

 Getting message "Insufficient Privilege" while trying to access graph under ProPerf application.

Cause

Error message "Insufficient Privillege" can be observed by a user when he/she will not have correct permission for that object associated with the graph.

Solution

  1. Refer NSP Security user guide available on OTN and check whether user has correct permission for viewing graph in ProPerf application.
  2. Check the privacy role of the profile associated with the owner of the object in security application. If the owner is TklcSrv then transfer the ownership of the object to other user.
  3. Check whether correct permission to the role associated with the user are selected under Configuration-->Security-->Object-->select object and click privacy or . If not then assign it.

 

 

 

 


 

References

http://docs.oracle.com/cd/E56061_01/docs.101/E55869_rev_2.pdf

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.