Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2001048.1
Update Date:2015-04-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  2001048.1 :   HOST_AUTO_POWER_ON and HOST_LAST_POWER_STATE Are Not Available in ILOM  


Related Items
  • Exadata X4-2 Hardware
  •  
  • Exadata X3-2 Hardware
  •  
  • Exadata Database Machine X2-8
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-10480805281>

Applies to:

Exadata Database Machine X2-8 - Version All Versions to All Versions [Release All Releases]
Exadata X4-2 Hardware - Version All Versions and later
Exadata X3-2 Hardware - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Parameters

HOST_AUTO_POWER_ON=disabled
HOST_LAST_POWER_STATE=enabled

are not available in ILOM.

Changes

 NONE

Cause

It's a known issue that the Power State Control settings are not available on X4800M2 nodes.
 
There are several bugs logged around this problem and the base bug is

Bug 18636184 : G5/G5+: ADD HOST POWER STATE CONTROL UNDER /SP/POLICY
 

Solution

The functionality will be add to ILOMs with newer Firmware.

Version 3.0.16.20.F and later

References

<BUG:18636184> - G5/G5+: ADD HOST POWER STATE CONTROL UNDER /SP/POLICY

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.