![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2000659.1 : T10000 - 349C Perm Errors
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek T10000 Tape Drive - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsFSC 349C permanent error CauseFSC Dictionary Description: SolutionIf and only if you can confirm that the drive took a 349C permanent error, the drive should be replaced. Note that we have a (tape drive) bug where 349C Retry errors are being reported by the drive as a permanent error in the trap and opening SRs. You must not replace any drives for this FSC unless you see in the event log where it shows the severity as permanent. Attachments This solution has no attachment |
||||||||||||||||
|