Solution Type Problem Resolution Sure Solution 1999787.1 : T10000A/B/C/D - FSC 5535 Load Errors
In this Document
Applies to:Sun StorageTek T10000 Tape Drive - Version All Versions to All Versions [Release All Releases]StorageTek T10000C Tape Drive - Version All Versions and later StorageTek T10000D Tape Drive - Version All Versions and later Information in this document applies to any platform. SymptomsFSC 5535 Load Errors. CauseThe file reel moved unexpectedly during the time when the cartridge leader should be stationary (ears seated). FSC Dictionary Description: SolutionT10000A/B/C/D - 5535 FSC The problem is most likely associated with excess slack in the tape. Each time the tape is loaded some of the slack is removed so it may load successfully the next time. 1 retry from the library is all that is typically needed to get the tape to load. Each time the tape is loaded some of the slack is removed so it may load successfully the next time. A code change was introduced in the T10000C release 3.63.101 and in the T10000D 4.10.106 release to help with 5535 errors.