Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1998615.1
Update Date:2016-10-05
Keywords:

Solution Type  Problem Resolution Sure

Solution  1998615.1 :   Secondary Far End Not Reachable On One Association  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-10479459921>

Applies to:

Oracle Communications EAGLE (Hardware) - Version EAGLE 45.0 and later
Information in this document applies to any platform.

Symptoms

The secondary far end is not reachable for a particular association

Cause

Far end was configured in uni homed and not in multi homed
By lack of secondary path on the far end side, Eagle which was configured as multi-homed could not reach the non existing secondary far end.

> rtrv-assoc:aname=ussducb101
 
     Eaglestp 15-03-27 11:46:09 EST  EAGLE5 45.0.1-64.70.35 
    ANAME Assoc101
          LOC      1301          IPLNK PORT A,B         LINK     A9           
          ADAPTER  M3UA          VER        M3UA RFC     
          LHOST    localhost
          ALHOST   alternatehost
          RHOST    remotehost
          ARHOST   ---
          LPORT    2905          RPORT      2905       
          ISTRMS   2             OSTRMS     2           BUFSIZE  200          
          RMODE    LIN           RMIN       120         RMAX     800          
          RTIMES   5             CWMIN      3000        UAPS     10           
          OPEN     YES           ALW        NO          RTXTHR   10           
          RHOSTVAL RELAXED     

 

> rept-stat-assoc:aname=Assoc101 

  Eaglestp 15-03-27 11:46:53 EST  EAGLE5 45.0.1-64.70.35
                           CARD IPLNK
   ANAME             LOC  PORT   LINK PST             SST              ASPID
   Assoc101          1301 A,B    A9   IS-ANR          RESTRICTED       undefined
    
    LSN       ANAME             ASP STATE      
    lsn101    Assoc101          ACTIVE        

 

=> We see in the below pass command, the lack of alternate remote IP address :

> pass:loc=1301:cmd="sctp -a Assoc101"
 
   Eaglestp 15-03-27 14:57:54 EST  EAGLE5 45.0.1-64.70.35
    Aname           Local              Local       Remote             Remote
                    Address            Port        Address            Port
    Assoc101        10.1xx.cd.xx       2905        10.aa.bac.ac       2905
                    10.1xx.xx.xx   

  
                                 Nets Data
    
         IP Address     10.aa.bac.ac      State   Reachable
               Port     2905                      Primary   YES
                MTU     1500                      cwnd   55296
           ssthresh     55296                     RTO   120  
    
         IP Address     10.aa.bad.ac      State   Not Reachable
               Port     2905                      Primary   NO
                MTU     1500                      cwnd   3000
           ssthresh     55296                     RTO   0   

 

 

Solution

The user has configured the far end in multi-homing with the expected ip@ 10.aa.bad.ac and it solved the issue


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.