![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1998615.1 : Secondary Far End Not Reachable On One Association
In this Document
Created from <SR 3-10479459921> Applies to:Oracle Communications EAGLE (Hardware) - Version EAGLE 45.0 and laterInformation in this document applies to any platform. SymptomsThe secondary far end is not reachable for a particular association CauseFar end was configured in uni homed and not in multi homed > rtrv-assoc:aname=ussducb101
Eaglestp 15-03-27 11:46:09 EST EAGLE5 45.0.1-64.70.35 ANAME Assoc101 LOC 1301 IPLNK PORT A,B LINK A9 ADAPTER M3UA VER M3UA RFC LHOST localhost ALHOST alternatehost RHOST remotehost ARHOST --- LPORT 2905 RPORT 2905 ISTRMS 2 OSTRMS 2 BUFSIZE 200 RMODE LIN RMIN 120 RMAX 800 RTIMES 5 CWMIN 3000 UAPS 10 OPEN YES ALW NO RTXTHR 10 RHOSTVAL RELAXED
> rept-stat-assoc:aname=Assoc101 Eaglestp 15-03-27 11:46:53 EST EAGLE5 45.0.1-64.70.35
=> We see in the below pass command, the lack of alternate remote IP address : > pass:loc=1301:cmd="sctp -a Assoc101"
SolutionThe user has configured the far end in multi-homing with the expected ip@ 10.aa.bad.ac and it solved the issue Attachments This solution has no attachment |
||||||||||||||||
|