![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
|||||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1997768.1 : SL3000 - Door Interlock Battery Needs Service, FSC3100 Warning
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL3000 Modular Library System - Version All Versions and laterInformation in this document applies to any platform. Typically the battery is good for several years. SymptomsDoor interlock battery needs service (Errors Started - 2015-03-30 13:08:18 Errors Stopped - 2015-03-30 13:08:18) 2015-04-09 14:44:54 HBC(1.0.0.0.0) 3100 - (1X) Door interlock battery needs service (Errors Started - 2015-03-30 13:08:18 Errors Stopped - 2015-03-30 13:08:18) ChangesNone Cause
SolutionThe PUN has the battery that monitors door status. The battery is not field replaceable, so the PUN will need to be replaced. SL3000 - How to Remove and Replace a PUN Card, ATR 2158641.1.2 (Doc ID 2158641.1) Attachments This solution has no attachment |
|||||||||||||||||||||||
|