Solution Type Problem Resolution Sure Solution 1996288.1 : Oracle ZFS Storage Appliance: 7420 cluster - The JBOD is Configured Incorrectly (Unable to upgrade IOMs)
In this Document
Created from <SR 3-10518005514> Applies to:Sun ZFS Storage 7420 - Version All Versions and later7000 Appliance OS (Fishworks) SymptomsAfter an Appliance Firmware Release upgrade to the latest version, the system unable to upgrade the 3 HP shelves firmware as both heads complains that they are not the owner of these shelves.
CauseThere was no pool configured on these 3 trays so the IOM's did not get updated.
SolutionCreated a pool and stopped and re-started AKD - this did not get the IOM's to upgrade either so we had to do it manually.
Once the firmware on one of the IOMs was manually upgraded ... the rest started upgrading by themselves... DCHQZFS7420-Head2# sesupgrade -i /usr/lib/ak/fw/ORACLE-DE2-24P-0018/DE2-24P.0018.fw /dev/scsi/ses/c6t50800200014B0AFEd0
device: /dev/scsi/ses/c6t50800200014B0AFEd0 vendor: ORACLE product: DE2-24P revision: 0010 serial: 1316FM4033 current status: none downloading 5275848 bytes: ok status: completed (need reset or power on)