Asset ID: |
1-72-1992312.1 |
Update Date: | 2017-05-19 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1992312.1
:
SL3000/LTO - LTO4 load FAILED resultCode = 6415 on Drive In SL3000 Library, Stuck Tape
Related Items |
- Sun StorageTek SL3000 Modular Library System
- HP LTO4 Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Created from <SR 3-10429884747>
Applies to:
HP LTO4 Tape Drive - Version All Versions and later
Sun StorageTek SL3000 Modular Library System - Version All Versions and later
Information in this document applies to any platform.
Symptoms
Drive @ Bay 23 gives Unit Attention - struck tape.
Mount: CLNU07 mounted on 1, 0,12,21
ACSSA> dis CLNU07 1,0,12,21 force
2015-03-08 08:57:04 0 drive 1, 0,12,21 reported a Unit Attention. ------> Drive @ Bay 23
ACSSA>
=====================================================
2015-03-16 09:47:15 Drive_Bay27(1.1.-3.1.1)
3357 - (26X) Drive Cannot Load Cartridge, hliLsm=0
JJ0012L4 (x1) JJ0475L4 (x1) JJ0500L4 (x3) JJ0549L4 (x1) JJ0776L4 (x1) JJ1119L4 (x1) JJ1275L4 (x2) JJ1396L4 (x1) JJ1415L4 (x1) JJ1484L4 (x1) JJ1546L4 (x1) JJ2264L4 (x3) JJ2333L4 (x1) JJ2419L4 (x3) JJ2882L4 (x2) JJ3630L4 (x1) JJ3679L4 (x1) JJ9059L4 (x1)
(Errors Started - 2015-03-16 09:17:59 Errors Stopped - 2015-03-16 09:47:00)
3955 - (75X) Error from device Code: 603 - Drive cartridge is present, drive 1,1,-3,1,1: load FAILED resultCode = 6415,
JJ0012L4 (x3) JJ0475L4 (x3) JJ0500L4 (x9) JJ0549L4 (x3) JJ0776L4 (x3) JJ1119L4 (x3) JJ1275L4 (x6) JJ1396L4 (x3) JJ1415L4 (x3) JJ1484L4 (x3) JJ2264L4 (x9) JJ2333L4 (x3) JJ2419L4 (x9) JJ2882L4 (x6) JJ3630L4 (x3) JJ3679L4 (x3) JJ9059L4 (x3)
(Errors Started - 2015-03-16 09:18:31 Errors Stopped - 2015-03-16 09:47:15)
2015-03-16T09:45:30.755, 0.0.0.0.0, 603, drive-director, /usr/local/bin/driveIf, error, 0000, 6415, "Director - loadResponse() drive 1,1,-3,1,1: load FAILED resultCode = 6415, cartLabel = JJ1484L4 "
2015-03-16T09:45:49.314, 0.0.0.0.0, 603, drive-director, /usr/local/bin/driveIf, error, 0000, 6415, "Director - loadResponse() drive 1,1,-3,1,1: load FAILED resultCode = 6415, cartLabel = JJ0500L4 "
2015-03-16T09:45:55.146, 0.0.0.0.0, 603, drive-director, /usr/local/bin/driveIf, error, 0000, 6415, "Director - loadResponse() drive 1,1,-3,1,1: load FAILED resultCode = 6415, cartLabel = JJ0500L4 "
2015-03-16T09:46:01.077, 0.0.0.0.0, 603, drive-director, /usr/local/bin/driveIf, error, 0000, 6415, "Director - loadResponse() drive 1,1,-3,1,1: load FAILED resultCode = 6415, cartLabel = JJ0500L4 "
2015-03-16T09:46:20.554, 0.0.0.0.0, 603, drive-director, /usr/local/bin/driveIf, error, 0000, 6415, "Director - loadResponse() drive 1,1,-3,1,1: load FAILED resultCode = 6415, cartLabel = JJ2419L4 "
2015-03-16T09:46:30.214, 0.0.0.0.0, 603, drive-director, /usr/local/bin/driveIf, error, 0000, 6415, "Director - loadResponse() drive 1,1,-3,1,1: load FAILED resultCode = 6415, cartLabel = JJ2419L4 "
2015-03-16T09:46:36.044, 0.0.0.0.0, 603, drive-director, /usr/local/bin/driveIf, error, 0000, 6415, "Director - loadResponse() drive 1,1,-3,1,1: load FAILED resultCode = 6415, cartLabel = JJ2419L4 "
2015-03-16T09:46:59.664, 0.0.0.0.0, 603, drive-director, /usr/local/bin/driveIf, error, 0000, 6415, "Director - loadResponse() drive 1,1,-3,1,1: load FAILED resultCode = 6415, cartLabel = JJ2264L4 "
2015-03-16T09:47:08.354, 0.0.0.0.0, 603, drive-director, /usr/local/bin/driveIf, error, 0000, 6415, "Director - loadResponse() drive 1,1,-3,1,1: load FAILED resultCode = 6415, cartLabel = JJ2264L4 "
2015-03-16T09:47:14.364, 0.0.0.0.0, 603, drive-director, /usr/local/bin/driveIf, error, 0000, 6415, "Director - loadResponse() drive 1,1,-3,1,1: load FAILED resultCode = 6415, cartLabel = JJ2264L4 "
Cause
Drive has unload issues.
Solution
Replaced defective tape drive.
Attachments
This solution has no attachment