Solution  1991703.1 :   SL150 - After Replacing The Robot Module The Library Is Showing Three Cartridges with Unreadable Volume Labels in the Mailslot  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-10437317000>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Volser numbers not showing up in the mailslot.

Media not being recognized in the mailslot.


CellDb text:
1.0
0,7,1,0,+,0,0,255,255,0,0,255,0,0
10,3,1,0,+,0,0,255,255,0,0,1,1,12                     <---------- CAP magazine locations show empty with no volsers.
11,3,1,0,+,0,0,255,255,0,0,1,1,13
12,3,1,0,+,0,0,255,255,0,0,1,1,14
13,3,1,0,+,0,0,255,255,0,0,1,1,15
500,2,1,0,+,0,0,255,255,1,0,1,1,11
501,2,1,0,+,0,0,255,255,2,0,1,2,11
502,2,1,0,+,0,0,255,255,3,0,2,1,11

 

 

Changes

Added new tapes into mailslot.

Cause

Labels are upside down on the media cartridges.

Solution

Replace the media labels on the cartridges to be right side up.