![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1991289.1 : SL8500 - FSC(3278): Library Dispatcher Took a Select Error
In this Document
Created from <SR 3-10447611715> Applies to:Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsFSC 3278, FSC3278, ATR error CauseLibrary error on the ILC interface. Library dispatcher took a read error, write error, or registration error. Example 2014-07-28T04:58:19.273, 1.0.0.0.0, root, default, internal, 0, error, 3278, "subId=3 Library dispatcher took an error during a read operation: Network error com.stortek.ats.elib.rpc.CommunicationException: read select error", library=ILC4 Currently an issue is opened to library code engineering investigated under Bug_18757170 to address errors reported as unrecoverable when they appear to recover without impact to customer operations. Note an excessive number of errors reported could also indicate a hardware error that should be investigated and acted upon. Hardware related items that can cause ILC errors reported as 3278: -ILC switch -Ethernet cables going from the ILC switch to Port_1A from the reporting library typically library id_1. -Ethernet cables from the ILC switch to the library referenced; example ILC4<library id_4>.
SolutionNo action taken; close alert. Attachments This solution has no attachment |
||||||||||||||||
|