Solution Type  Problem Resolution Sure

Solution  1991067.1 :   T10000A/B/C/D - 34A3 FSC, DC_FSC_CMPR_ERROR  


Related Items
  • Sun StorageTek T10000 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

Sun StorageTek T10000 Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

 34A3 FSC, FSC34A3

Cause

FSC Dictionary Description:
MODEL = T10000A,B,C,D
FSC = 34A3
(FSC Match Found in Rev. 3.62)


FSC: 34A3 DC_FSC_CMPR_ERROR

MIM Code: TOLERANCE

FRU: HARDWARE CONF: 95%

FRU: MICROCODE CONF: 5%

Summary: |INVALID UCODE |REGISTER VALUE | *** |

Field Text:
This symptom indicates that there was a compressor error detected while a trasfer was happening over compressor port.

Solution

 It is normal to see temp 34A3 FSCs in the event log.  If you are able to confirm that the error is a permanent error in the tape drive event log ony then should the drive be replaced.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.