Solution Type  Problem Resolution Sure

Solution  1991056.1 :   9x40 And T10000A/B/C/D - Write Perm Error  


Related Items
  • Sun StorageTek 9840 Tape Drive
  •  
  • Sun StorageTek 9940 Tape Drive
  •  
  • Sun StorageTek T10000 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution
References


Applies to:

Sun StorageTek 9940 Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Sun StorageTek T10000 Tape Drive - Version All Versions to All Versions [Release All Releases]
Sun StorageTek 9840 Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

Write Perm errors.

Permanent write errors.

Cause

 Write Perm errors.

Solution

For any of the Write Perm errors perform the following test:
1. Upload an event log into the SR. Process to collect the tape drive event log

2. Look at the results to see if a drive is called out as defective or if the tape is as fault.

3. If the drive is defective a replacement drive needs to be dispatched.

4. If the tape is defective this tape should be replaced. Media replacement process

 

 


Attachments