![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1991056.1 : 9x40 And T10000A/B/C/D - Write Perm Error
In this Document
Applies to:Sun StorageTek 9940 Tape Drive - Version Not Applicable to Not Applicable [Release N/A]Sun StorageTek T10000 Tape Drive - Version All Versions to All Versions [Release All Releases] Sun StorageTek 9840 Tape Drive - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. SymptomsWrite Perm errors. Permanent write errors. CauseWrite Perm errors. SolutionFor any of the Write Perm errors perform the following test: 2. Look at the results to see if a drive is called out as defective or if the tape is as fault. 3. If the drive is defective a replacement drive needs to be dispatched. 4. If the tape is defective this tape should be replaced. Media replacement process
Attachments This solution has no attachment |
||||||||||||||||||
|