![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1991044.1 : T10000A/B/DC/D - 5204 Errors On Cleaning Tapes
In this Document
Applies to:Sun StorageTek T10000 Tape Drive - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. Symptoms5204 errors on cleaning tape. FSC5204 CauseFSC Dictionary Description: Solution5204 errors on cleaning tape in the event log are normal and can be ignored. There is a bug in older T10KA/B microcode where perm error traps were being sent back from the drive for temp 5204 errors on tapes. Once verified, these SRs can be closed when they come in.
If this error is for data tapes then force a drive dump for analysis. For multiple data tapes failing with this error code on the same drive you will need to replace the drive. Attachments This solution has no attachment |
||||||||||||||||
|