Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1991044.1
Update Date:2017-10-04
Keywords:

Solution Type  Problem Resolution Sure

Solution  1991044.1 :   T10000A/B/DC/D - 5204 Errors On Cleaning Tapes  


Related Items
  • Sun StorageTek T10000 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

Sun StorageTek T10000 Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

5204 errors on cleaning tape.

FSC5204

Cause

FSC Dictionary Description:
MODEL = T10000C
FSC = 5204
(FSC Match Found in Rev. 3.62)


FSC: 5204 SM_FSC_COMMAND_OUT_OF_CONTEXT

MIM Code: NONE

FRU: MICROCODE CONF: 100%

Summary: |INVALID UCODE |MESSAGE RECEIVED| *** |

Field Text:
State Machine command out of context.

Solution

5204 errors on cleaning tape in the event log are normal and can be ignored. There is a bug in older T10KA/B microcode where perm error traps were being sent back from the drive for temp 5204 errors on tapes.  Once verified, these SRs can be closed when they come in.

 

If this error is for data tapes then force a drive dump for analysis. For multiple data tapes failing with this error code on the same drive you will need to replace the drive.


Attachments
This solution has no attachment