![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1989085.1 : Oracle ZFS Storage Appliance: Four second delay seen for automount directories
In this Document
Created from <SR 3-10085083361> Applies to:Sun ZFS Storage 7420 - Version All Versions and laterSun ZFS Storage 7320 - Version All Versions and later Sun ZFS Storage 7120 - Version All Versions and later Oracle ZFS Storage ZS3-2 - Version All Versions and later Oracle ZFS Storage ZS3-BA - Version All Versions and later 7000 Appliance OS (Fishworks) SymptomsWhen automounter from a client mounts a filesystem delays of 4 seconds or greater are seen. CauseThe client automount configuration had 3 paths to the array defined. In the customers network configuration not all paths defined from client to array were consistently available. Automount checks all paths and any that are not responding will have a 4 second timeout. SolutionThe customers network configuration was checked and corrected such that access from the client to the array was available on all paths.
References<NOTE:1175804.1> - NFS and NIS Interaction with Network Firewalls<NOTE:1433313.1> - Why is my nfs mount not showing rsize and wsize to despite setting 1MB mount options? <NOTE:1004583.1> - Increasing ncsize solves nfs performance problem on Solaris Attachments This solution has no attachment |
||||||||||||||||||
|