Solution Type  Problem Resolution Sure

Solution  1983812.1 :   showgwports shows 0A-ETH port in reset state  


Related Items
  • Exalogic Elastic Cloud X4-2 Hardware
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Infiniband
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-9704587808>

Applies to:

Exalogic Elastic Cloud X4-2 Hardware - Version X4 and later
Oracle Exalogic Elastic Cloud X2-2 Hardware - Version X2 and later
Information in this document applies to any platform.

Symptoms

ibgwswx#showgwports

 

Port      Bridge      Adminstate Link  State       MTU  TxPause  RxPause
-------------------------------------------------------------------------
0A-ETH-1  Bridge-0-2  Enabled    Up    Up          9600 Global   Global
0A-ETH-2  Bridge-0-2  Enabled    Up    Reset       9600 Global   Global <<<<<<<<<


Cause

 In this case a vlan has not been created on 0A-ETH-2

Solution

 This state will change from Reset to Up when a VLAN is created for the connector 0A-ETH-2 .

In this case if using vlan 12 and default partition the CLI command would be:

ibgwswx#createvlan 0A-ETH-2 -vlan 12 -pkey default

For Exalogic virtual, all changes should be made using Ops Centre and not the switch CLI

 

bgwswx#showgwports

Port      Bridge      Adminstate Link  State       MTU  TxPause  RxPause
-------------------------------------------------------------------------
0A-ETH-1  Bridge-0-2  Enabled    Up    Up          9600 Global   Global
0A-ETH-2  Bridge-0-2  Enabled    Up    Up          9600 Global   Global

 