![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1983812.1 : showgwports shows 0A-ETH port in reset state
In this Document
Created from <SR 3-9704587808> Applies to:Exalogic Elastic Cloud X4-2 Hardware - Version X4 and laterOracle Exalogic Elastic Cloud X2-2 Hardware - Version X2 and later Information in this document applies to any platform. Symptomsibgwswx#showgwports
Port Bridge Adminstate Link State MTU TxPause RxPause CauseIn this case a vlan has not been created on 0A-ETH-2 SolutionThis state will change from Reset to Up when a VLAN is created for the connector 0A-ETH-2 . In this case if using vlan 12 and default partition the CLI command would be: ibgwswx#createvlan 0A-ETH-2 -vlan 12 -pkey default For Exalogic virtual, all changes should be made using Ops Centre and not the switch CLI
bgwswx#showgwports Port Bridge Adminstate Link State MTU TxPause RxPause
Attachments This solution has no attachment |
||||||||||||||||
|