![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1981021.1 : SC.BAT.V_BAT error during boot
In this Document
Created from <SR 3-10260181781> Applies to:Sun Fire V445 Server - Version All Versions and laterSun Fire V440 Server - Version All Versions and later Sun Netra 440 Server - Version All Versions and later Information in this document applies to any platform. SymptomsServer not booting due to a defective SC Battery
SC Alert: SC initiating soft host system shutdown due to fault at SC.BAT.V_BAT. <<--- Defective Battery
SC Alert: SC Request to Power Off Host. <<--- Due to the battery issue the system shutdown itself off Probing system devices Probing memory ChassisSerialNumber 0743BD0A22 Probing I/O buses Starting RTC .. screen not found. keyboard not found. Keyboard not present. Using ttya for input and output. Probing system devices Probing memory ChassisSerialNumber 0743BD0A22 Probing I/O buses Starting RTC .. Sun Fire V445, No Keyboard Copyright 2007 Sun Microsystems, Inc. All rights reserved. OpenBoot 4.25.9, 16384 MB memory installed, Serial #78260534. Ethernet address 0:14:4f:aa:29:36, Host ID: 84aa2936. Running diagnostic script obdiag/normal Testing /ebus@1f,464000/flashprom@0,0 Testing /ebus@1f,464000/serial@0,c2c000 {3} ok SC Alert: Host system has shut down. CauseThe root cause of this issue is dropping voltage of the battery over time, per normal usage. The battery is located on the System Controller (SC). SolutionReplace the failing ALOM Battery as soon as available. Attachments This solution has no attachment |
||||||||||||||||
|