Asset ID: |
1-72-1967992.1 |
Update Date: | 2016-08-29 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1967992.1
:
INC000000092846 Unable To Access The E5-MS GUI After Updating The Java To 1.7
Related Items |
- Oracle Communications EAGLE (Hardware)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
|
In this Document
Created from <SR 3-10197038561>
Applies to:
Oracle Communications EAGLE (Hardware) - Version EMS 43.x and later
Information in this document applies to any platform.
Symptoms
Unable to access GUI Web page for E5-MS
Cause
User is using wrong URL
Solution
Advised user to prepend the url information with https://
References
<NOTE:1920295.1> - GUI applications are not accessible. Element Management System Release 43.0.0:
<NOTE:1964277.1> - Unable To Open E5MS GUI
Attachments
This solution has no attachment