Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1965602.1
Update Date:2017-05-03
Keywords:

Solution Type  Problem Resolution Sure

Solution  1965602.1 :   SL150 - DRIVE_UNSPECIFIED_FAILURE - Fault Code:9022 Message In Error Log  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  


SL150 Error log has posted a 9022 Error message

In this Document
Symptoms
Changes
Cause
Solution
References


Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
SL150

Symptoms


Drive(s) that appear to be in a Fatal status: HU*12345L12 (example)
FRU: DriveAssembly - Current Status: Inoperative.

DRIVE_UNSPECIFIED_FAILURE - Fault Code:9022

Probable Failed Components

1. Module X Top/Bottom DriveAssembly
2. Module X Controller
3. Module X Motherboard

Where x is the drive number.

Changes

 None

Cause

A non-specific drive error has occured

Drive connection has been lost

Solution


Actions to Take

1.  Reseat/replace drive.
2.  Reseat/replace controller.
3.  Replace motherboard

If still in error please send in support bundle with newly logged case.

References

<NOTE:1599469.1> - SL150 - How to Generate and Retrieve a Service Bundle (Health / Error Log) From the StorageTek SL150 Modular Tape Library Firmware 2.01

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.