Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1965374.1
Update Date:2017-08-04
Keywords:

Solution Type  Problem Resolution Sure

Solution  1965374.1 :   SL150 - Error With Fibre Loops On The Backup Server. Drives going offline  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
  • HP LTO5 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-10084536253>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
HP LTO5 Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Error with fibre loops on the backup server. It goes online and offline.

2015-01-04T11:58:43.204,      0.0.0.0.0, 000,          tti-dbg,                 ,   warn, 0000, 0000, "ADT: sendPkt: Drive: 2 - Was logged out, had to renegotiate the link!"
2015-01-14T01:58:18.346,      0.0.0.0.0, 000,          tti-dbg,                 ,   warn, 0000, 0000, "ADT: sendPkt: Drive: 3 - Was logged out, had to renegotiate the link!"
2015-01-17T01:51:37.475,      0.0.0.0.0, 000,          tti-dbg,                 ,   warn, 0000, 0000, "ADT: sendPkt: Drive: 2 - Was logged out, had to renegotiate the link!"

Loop OFFLINE/ONLINEs still exist:
Jan 14 02:10:29 oranbu1 qlc: [ID 439991 kern.info] NOTICE: Qlogic qlc(7,1): Loop OFFLINE
Jan 14 02:11:27 oranbu1 qlc: [ID 439991 kern.info] NOTICE: Qlogic qlc(7,1): Loop ONLINE

Jan 17 02:04:30 oranbu1 qlc: [ID 439991 kern.info] NOTICE: Qlogic qlc(0,0): Loop OFFLINE
Jan 17 02:05:28 oranbu1 qlc: [ID 439991 kern.info] NOTICE: Qlogic qlc(0,0): Loop ONLINE

Jan 20 02:09:44 oranbu1 qlc: [ID 439991 kern.info] NOTICE: Qlogic qlc(7,1): Loop OFFLINE
Jan 20 02:10:42 oranbu1 qlc: [ID 439991 kern.info] NOTICE: Qlogic qlc(7,1): Loop ONLINE

Cause

Search on driver-name qlc (SunFC Qlogic FCA v20131114-4.03) ----------Get patch 149175-05.

This patch was obsoleted by patch 149175-06, which was obsoleted by patch 149175-08.

Solution

Upgrade patch on HBA.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.