Asset ID: |
1-72-1965374.1 |
Update Date: | 2017-08-04 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1965374.1
:
SL150 - Error With Fibre Loops On The Backup Server. Drives going offline
Related Items |
- StorageTek SL150 Modular Tape Library
- HP LTO5 Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
|
In this Document
Created from <SR 3-10084536253>
Applies to:
StorageTek SL150 Modular Tape Library - Version All Versions and later
HP LTO5 Tape Drive - Version All Versions and later
Information in this document applies to any platform.
Symptoms
Error with fibre loops on the backup server. It goes online and offline.
2015-01-04T11:58:43.204, 0.0.0.0.0, 000, tti-dbg, , warn, 0000, 0000, "ADT: sendPkt: Drive: 2 - Was logged out, had to renegotiate the link!"
2015-01-14T01:58:18.346, 0.0.0.0.0, 000, tti-dbg, , warn, 0000, 0000, "ADT: sendPkt: Drive: 3 - Was logged out, had to renegotiate the link!"
2015-01-17T01:51:37.475, 0.0.0.0.0, 000, tti-dbg, , warn, 0000, 0000, "ADT: sendPkt: Drive: 2 - Was logged out, had to renegotiate the link!"
Loop OFFLINE/ONLINEs still exist:
Jan 14 02:10:29 oranbu1 qlc: [ID 439991 kern.info] NOTICE: Qlogic qlc(7,1): Loop OFFLINE
Jan 14 02:11:27 oranbu1 qlc: [ID 439991 kern.info] NOTICE: Qlogic qlc(7,1): Loop ONLINE
Jan 17 02:04:30 oranbu1 qlc: [ID 439991 kern.info] NOTICE: Qlogic qlc(0,0): Loop OFFLINE
Jan 17 02:05:28 oranbu1 qlc: [ID 439991 kern.info] NOTICE: Qlogic qlc(0,0): Loop ONLINE
Jan 20 02:09:44 oranbu1 qlc: [ID 439991 kern.info] NOTICE: Qlogic qlc(7,1): Loop OFFLINE
Jan 20 02:10:42 oranbu1 qlc: [ID 439991 kern.info] NOTICE: Qlogic qlc(7,1): Loop ONLINE
Cause
Search on driver-name qlc (SunFC Qlogic FCA v20131114-4.03) ----------Get patch 149175-05.
This patch was obsoleted by patch 149175-06, which was obsoleted by patch 149175-08.
Solution
Upgrade patch on HBA.
Attachments
This solution has no attachment