Asset ID: |
1-72-1965331.1 |
Update Date: | 2017-03-13 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1965331.1
:
PmiaMonitor Drops Packets for the Socket 254, Causing the Decrease of DFP Traffic
Related Items |
- Oracle Communications Performance Intelligence Center (PIC) Software
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
|
In this Document
Created from <SR 3-10159546181>
Applies to:
Oracle Communications Performance Intelligence Center (PIC) Software - Version 7.5 and later
Tekelec
Symptoms
Input MSUs traffic decreased for several Data Flow Processing (DFP).
Changes
Cause
"pmia" processes filters traffic. As per the pmia Counters verifications (command: 'cfgPmia pmiaCounters' to display these counters), the socket 254 drops all packets. This makes the traffic decreasing, with loss of data.
Solution
The best action is to disable "SigtranMonitor" (put the value at 0) on the PMF "Settings" (from CCM, right click on the PMF).
Attachments
This solution has no attachment