Solution Type  Problem Resolution Sure

Solution  1965331.1 :   PmiaMonitor Drops Packets for the Socket 254, Causing the Decrease of DFP Traffic  


Related Items
  • Oracle Communications Performance Intelligence Center (PIC) Software
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-10159546181>

Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 7.5 and later
Tekelec

Symptoms

Input MSUs traffic decreased for several Data Flow Processing (DFP).

Changes

 

Cause

"pmia" processes filters traffic. As per the pmia Counters verifications (command: 'cfgPmia pmiaCounters' to display these counters), the socket 254 drops all packets. This makes the traffic decreasing, with loss of data. 

Solution

The best action is to disable "SigtranMonitor" (put the value at 0) on the PMF "Settings" (from CCM, right click on the PMF).
 