Solution Type  Problem Resolution Sure

Solution  1964347.1 :   Sun Storage 7000 Unified Storage System: Affiliation failure seen on boot on single node system.  


Related Items
  • Sun Storage 7410 Unified Storage System
  •  
  • Sun Storage 7310 Unified Storage System
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-10133670461>

Applies to:

Sun Storage 7410 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 7310 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A]
7000 Appliance OS (Fishworks)

Symptoms

System 'slow'

Messages seen at boot:

Sun Storage 7410 Version ak/SUNW,toro@2011.04.24.9.2,1-1.50
Copyright 2015 Sun Microsystems, Inc.  All rights reserved.
Use is subject to license terms.

WARNING: /pci@0,0/pci10de,375@f/pci1000,3150@0 (mpt1):
      Cannot access device - assigned to another host (affiliation failure). WWN=50016360001f43d7 target=81
WARNING: /pci@0,0/pci10de,375@f/pci1000,3150@0 (mpt1):
      Cannot access device - assigned to another host (affiliation failure). WWN=50016360001f43d2 target=76
WARNING: /pci@0,0/pci10de,375@f/pci1000,3150@0 (mpt1):
      Cannot access device - assigned to another host (affiliation failure). WWN=50016360001f43cd target=71
WARNING: /pci@0,0/pci10de,375@f/pci1000,3150@0 (mpt1):
      Cannot access device - assigned to another host (affiliation failure). WWN=50016360001f43c8 target=66
WARNING: /pci@0,0/pci10de,375@f/pci1000,3150@0 (mpt1):
      Cannot access device - assigned to another host (affiliation failure). WWN=50016360001f43ca target=68
WARNING: /pci@0,0/pci10de,375@f/pci1000,3150@0 (mpt1):
      Cannot access device - assigned to another host (affiliation failure). WWN=50016360001f43c4 target=62
WARNING: /pci@0,0/pci10de,375@f/pci1000,3150@0 (mpt1):
      Cannot access device - assigned to another host (affiliation failure). WWN=50016360001f43c7 target=65
WARNING: /pci@0,0/pci10de,375@f/pci1000,3150@0 (mpt1):
      Cannot access device - assigned to another host (affiliation failure). WWN=50016360001f43c0 target=58
WARNING: /pci@0,0/pci10de,375@f/pci1000,3150@0 (mpt1):
      Cannot access device - assigned to another host (affiliation failure). WWN=50016360001f43c1 target=59
WARNING: /pci@0,0/ci10de,376@e/pci1000,3150@0 (mpt0):
      Cannot access device - assigned to another host (affiliation failure). WWN=50016360001f43d4 target=78
WARNING: /pci@0,0/pci10de,376@e/pci1000,3150@0 (mpt0):
      Cannot access device - assigned to another host (affiliation failure). WWN=50016360001f43d0 target=74

  

'zpool status' hangs and takes several minutes to return report on all healthy disks.

 

Changes

Possible misconfiguration since installation.

Possible changes to SAS cable configuration including removal of JBODs, leaving too many HBA and SAS connections attached to single remaining SATA JBOD.

 

Cause

Single node has 4 SAS cable connections to single SATA JBOD.

This breaks the SATA affiliation as the JBOD is connected like a cluster - but to only one node.

 

Solution

1) Shutdown array head
2) Remove extra SAS connections to JBOD - Configure so that each HBA has only one connection to a SIM
3) Retest for fault.
 