![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1964140.1 : HP LTO - No Default IP Address For HP LTO6 Drive or HP LTO5 Drive
new install LTO5 and LTO 6 Drive and Drive trays .. can not access IP address 10.0.0.1 also could not reset Drive to IP Address 10.0.0.1 bad internal cable --- The part # of this is 7069871 (CBL ASSY, HP LTO5 ETHERNET, SL30/85). This cable doesn't show available anywhere in logistic so the "no part" process will need to be followed. In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:HP LTO5 Tape Drive - Version All Versions to All Versions [Release All Releases]HP LTO6 Tape Drive - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsCan not access IP address 10.0.0.1 No an issue that has been heard of. No HP drive dumps sent in as customer can not attach to the drive with default address 10.0.0.1 ChangesNew install of LTO5 and LTO6 Drive/Tray. CauseBad internal cable. SolutionReplace defective cable. The part number is 7069871 (CBL ASSY, HP LTO5 ETHERNET, SL30/85). This cable does not show available anywhere in logistics. The "no part" process will need to be followed. How to Order Parts Using the 'No Parts Process', NOPRT (Doc ID 1285688.1) References<NOTE:1020770.1> - HP LTO - Dione Log Extraction Procedure<NOTE:1932475.1> - HP/IBM LTO4/5 - (Encrypted) and Higher Generation Drives On Open or Public Networks Attachments This solution has no attachment |
||||||||||||||||||||
|