Solution Type Problem Resolution Sure Solution 1964110.1 : T10000A/B - 091F SNO Errors
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek T10000B Tape Drive - Version All Versions to All Versions [Release All Releases]Sun StorageTek T10000A Tape Drive - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SNO = Should Not Occur Symptoms091F SNO on a T10000A or T10000B drive. FSC091F CauseIf you are running with code above 1.48.105 then the cause of this type of error is due to a bit flip in memory. SolutionThis is typically a rare occurrence that will usually not re-occur. If one sees the same failure twice on the same drive, then replace the drive. Attachments This solution has no attachment |
||||||||||||||||
|