Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1963253.1
Update Date:2015-06-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  1963253.1 :   Issues With ODA upgrade to 12c failed with second node  


Related Items
  • Oracle Database Appliance X4-2
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Database Appliance>DB: ODA_EST
  •  


When try to upgrade ODA from 2.9 -> 12.1.2.1.0 , the GI upgrade failed and cannot upgrade succesful

Created from <SR 3-10120117401>

Applies to:

Oracle Database Appliance X4-2 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Updating ODA from 2.9.0.0.0 to 12.1.2.1.0.
Infra has been  successfully patched as described in MOS <note 19690105>.
After successful reboot of both nodes, the following command has been run (from node 1) 'oakcli update -patch 12.1.2.1.0 --gi'

It seems to complete successfully, except for setting up SSH for grid (to node 1). - Patching on node 0 appears to have completed successfully.
It seems it is a wrong password for grid user on node 1.

Changes

upgrade of GI on any 12.1.2.1 or higher version of the ODA

Cause

When the first time GI upgrade (oakcli update -patch 12.1.2.1.0 --gi" fails, without cleanup the second time or later the GI upgrade will not continue under such situation.

Solution

Run:

 oakcli update -patch 12.1.2.1.0 --clean

and re-run:

 oakcli update -patch 12.1.2.0.0 --gi

 

See note 888888.1 for possible known issues depending on version


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback