![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1956669.1 : 12C Database reports KFOD Error During Oracle Exadata Database Machine Discovery : "DiscoveryWarning: kfod returns status 126"
kfod returns status 126; KFOD Error; OSSCONF; 12c ;Oracle Exadata Database Machine Discovery; Database Machine Discovery; DiscoveryWarning: kfod returns status 126; Applies to:Exadata Database Machine X2-2 Full Rack - Version All Versions to All Versions [Release All Releases]Oracle Platinum Services - Version N/A to N/A Information in this document applies to any platform. SymptomsFollowing error is reported during Oracle Exadata Database Machine Discovery on 12C database. <Machine1> : KFOD Error>DiscoveryWarning: kfod returns status 126. Please check the OSSCONF environment variable and make sure that cellinit.ora and cellip.ora are readable by the EM agent. Cause This is a known bug in the kfod wrapper script: Unpublished BUG 19682778 - 121021GIPSU: KFOD FILE IN RAC HOME NOT CORRECT AFTER APPLYING GIPSU SolutionWorkaround: ------------------ References<BUG:19682775> - 121021GIPSU: KFOD FILE IN RAC HOME NOT CORRECT AFTER APPLYING GIPSU<BUG:19682778> - 121021GIPSU: KFOD FILE IN RAC HOME NOT CORRECT AFTER APPLYING GIPSU Attachments This solution has no attachment |
||||||||||||
|