Solution Type  Problem Resolution Sure

Solution  1956018.1 :   Exadata: Database node booting in Loop with log in console: /opt/MegaRAID/MegaCli/MegaClii64-LDSetProp -DisDskCache -Lall -a0 -nolog  


Related Items
  • Exadata Database Machine X2-2 Full Rack
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  




Created from <SR 3-10032145611>

Applies to:

Exadata Database Machine X2-2 Full Rack - Version All Versions and later
Linux x86-64

Symptoms

 Exadata Database node was rebooted for maintenance and below logs keep on coming when checked ILOM Console and serer was in booting loop.

/opt/MegaRAID/MegaCli/MegaClii64-LDSetProp -DisDskCache -Lall -a0 -nolog

Cause

MegaCli64 script size is 0.

[root@Lab ~]# ls -l /opt/MegaRAID/MegaCli
total 504
-rw-r--r-- 1 root root 0 Jul 26 01:28 install.log
lrwxrwxrwx 1 root root 48 Jul 26 01:28 libstorelibir-2.so -> /opt/MegaRAID/MegaCli/libstorelibir-2.so.13.05-0
-r-x------ 1 root root 510200 Dec 19 2012 libstorelibir-2.so.13.05-0
-rwxr-xr-x 1 root root 0 Dec 17 17:32 MegaCli64

 

Service Precell is used to execute /opt/MegaRAID/MegaCli/MegaCli64 to perform pre-boot checks.

[root@xor1db01 ~]# chkconfig --list |grep -i "precell"
precell 0:off 1:off 2:on 3:on 4:on 5:on 6:off

 

Solution

  1. Reboot (Power Cycle) the Database node.
  2. From Serial console, pressed keyboard I once informed "Welcome to ... press I to enter interactive startup"
  3. Disabled precell on this boot (This is one time setting).
  4. Verified server came up without any issue.
  5. Copy /opt/MegaRAID/MegaCli/MegaCli64 from working Database node to overwrite counterpart on this problematic Database node.
  6. Rebooted the Database node.