CoreSystemController Is Not Stable. It Switches Over From One Blade To Another And Backwards
Related Items |
- Oracle Communications Subscriber Data Management (SDM)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Broadband Network Solutions>SN-SND: Tekelec SDM
|
CoresystemController switching over frequently and sometimes generates an oampmanager coredump
In this Document
Created from <SR 3-10002864051>
Applies to:
Oracle Communications Subscriber Data Management (SDM) - Version SDM 9.0.5 and later
Information in this document applies to any platform.
Symptoms
CoreSystemController is switching over every 6 hours to other blade.
Changes
Too Many provisioning requests done in one maintenance window.
Cause
Table RequestLog had almost 12GB of data stored, so when the data was attempted to be flushed to files, the service was going Out of Service (OOS) and oampmanager was going OOS.
Solution
Delete all data in RequestLog table.