![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1955259.1 : SL8500/T100000D - SLS0874A Message
In this Document
Created from <SR 3-10007640991> Applies to:Sun StorageTek SL3000 Modular Library System - Version Not Applicable to Not Applicable [Release N/A]Sun StorageTek T10000 Data Cartridge - Version Not Applicable and later Information in this document applies to any platform. Symptoms"SLS0874A MANUALLY REMOVE CART "DG0004" FROM ACS 00 LSM 00" during HSC start up.
ChangesEnter new diag cart to library after new SL3000 installation CauseDG0004 is put in system slot Incorrect DG label provided from sales rep. (Received error bunch carts). DG label format; DG{space}nnn ], where “DG{space}” is the diagnostic cartridge identifier, and “nnn” is a sequence of numbers (such as DG 001, and DG 019). Location : 1,1,3,1,49 Sample mis-labeled cart for DG00001.
SolutionReplaced proper DG label. Attachments This solution has no attachment |
||||||||||||||||||
|