Symptoms
Changes
Cause
Solution


Created from <SR 3-10007640991>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version Not Applicable to Not Applicable [Release N/A]
Sun StorageTek T10000 Data Cartridge - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

"SLS0874A MANUALLY REMOVE CART "DG0004" FROM ACS 00 LSM 00" during HSC start up.

 

 

Changes

 Enter new diag cart to library after new SL3000 installation

Cause

DG0004 is put in system slot

Incorrect DG label provided from sales rep. (Received error bunch carts).

DG label format;

DG{space}nnn ], where “DG{space}” is the diagnostic cartridge identifier, and “nnn” is a sequence of numbers (such as DG 001, and DG 019).

Location : 1,1,3,1,49
                   Location Type : sysCell
                   Media Type : T10000C
                   Type : data
                   Cartridge : DG0004T2

Sample mis-labeled cart for DG00001.

Mis-labeled diag cart

 

Solution

Replaced proper DG label.