Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1951268.1
Update Date:2016-08-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  1951268.1 :   Measurement Files (*.csv) Created and Sent By Mate Eagle STPs Are Working Intermitently.  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-9961048701>

Applies to:

Oracle Communications EAGLE (Hardware) - Version EAGLE 42.x to EAGLE 44.x [Release EAGLE 42.0 to EAGLE 44.0]
Tekelec

Symptoms

ERROR
-------------------------------------------------
Eagle Signalling Transfer Point (STP) E5-OAM Integrated Measurements Subsystem is sending measurement files *.csv to File Transfer Protocol (FTP) servers intermitently and STPs are generating Unsolicited Information Messages (UIM) 1254 "Scheduled transfer failure" and 1253 "Report transfer failure FTP Server".

    ****Logged  14-12-03  12:35:11****
    0018.1254    CARD 1113     INFO    Scheduled transfer failure
                 IP: ---------------         FTP Error: 0
                 File Name: -------------------------------
                 Report Date:14-12-03  Time:12:35:10
    ****Logged  14-12-03  12:35:10****
    0017.1253    CARD 1113     INFO    Report transfer failure FTP Server
                 IP: 10.#.#.##               FTP Error: 597
                 File Name: stpabc_avl-link_1203_1200.csv  
                 Report Date:14-12-03  Time:12:35:10

WHAT IS WORKIN?
-------------------------------------------------
Measurement files are sent intermitently.

ENVIRONMENT
-------------------------------------------------
Product and Version:EAGLE5 44.0.2-64.34.16
Platform: E5-OAM Integrated Measurements


BUSINESS IMPACT
-------------------------------------------------
The issue has the following business impact:
Some measurement files are lost.

Cause

This issue is caused because Eagle STP's E5-OAM Integrated Measurements Subsystem is not working properly.
 
EVIDENCE OF CAUSE:
-------------------------------------------------

Based on collected logs, measurement files/report *.csv are not sent properly to FTP servers because of FTP client packet send failure (FTP Error: 597)


REFERENCES:
-------------------------------------------------
Docs:

Unsolicited Alarm and Information Messages
 

Solution


To implement the solution, please execute the following steps on a low traffic period (maintenance window), starting on one STP and then work on the mate STP:

1. Identify the active Maintenance and Administration Subsystem Processor (MASP) and standby MASP by running rept-stat-meas command:

  > rept-stat-meas
 
  stp_clli yy-mm-dd hh:mm:ss TS EAGLE5 44.0.2-64.34.16
  rept-stat-meas
  Command entered at terminal #20.
;
  
  Command Accepted - Processing
  stp_clli yy-mm-dd hh:mm:ss TS EAGLE5 44.0.2-64.34.16
  PST SST AST
  MEAS SS IS-NR Active -----
  ALARM STATUS = No Alarms
  
  CARD VERSION TYPE PST SST AST
  1113 P 134-034-016 E5MCAP IS-NR Active -----
  IP Link A IS-NR Active -----
  1115 134-034-016 E5MCAP IS-NR Standby -----
  IP Link A IS-NR Active -----
  
  CARD 1113 ALARM STATUS = No Alarms
  CARD 1115 ALARM STATUS = No Alarms
  
  Command Completed.


2.Initialize standby E5-MASP card by running this command:

init-card:loc=<Standby E5-MASP card location>

3.Initialize active E5-MASP card by running this command, take into account that this action will cause a MASP switchover:

init-card:loc=<Active E5-MASP card location>


4. Proceed with mate STP.
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.