![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1950795.1 : SL3000/SL8500 - SLConsole Timeout During Installation Burn-In Testing
In this Document
Applies to:Sun StorageTek SL3000 Modular Library System - Version All Versions and laterSun StorageTek SL8500 Modular Library System - Version All Versions and later Information in this document applies to any platform. SymptomsSLConsole Timeout During Installation Burn-In Testing If running burn-in testing, the same SLConsole timeout that causes the panel to logoff, will also stop the diagnostics. CauseLimitation of parameters. SolutionUse the following command to extend the login timeout to 168 hours (1 week) during installation testing. If the customer desires, it can be set back to the default of 6 hours when the installation is complete. SL8500> config pliAuth set 168 Note: The operator panel, any SLConsole or SSH session will timeout after the specified interval, regardless of intervening use or access of the interfaces. If diagnostics stop there will be a login prompt on the screen for EACH routine that was running when the login timed out. You should be able to login to multiple requests and one-by-one the tests should resume. Attachments This solution has no attachment |
||||||||||||||||
|