Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1950795.1
Update Date:2017-05-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  1950795.1 :   SL3000/SL8500 - SLConsole Timeout During Installation Burn-In Testing  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions and later
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

 SLConsole Timeout During Installation Burn-In Testing

If running burn-in testing, the same SLConsole timeout that causes the panel to logoff, will also stop the diagnostics.

Cause

 Limitation of parameters.

Solution

Use the following command to extend the login timeout to 168 hours (1 week) during installation testing.  If the customer desires, it can be set back to the default of 6 hours when the installation is complete.

SL8500> config pliAuth set 168

SL8500> config pliAuth set [6,24,48,72,168]

Note: The operator panel, any SLConsole or SSH session will timeout after the specified interval, regardless of intervening use or access of the interfaces. If diagnostics stop there will be a login prompt on the screen for EACH routine that was running when the login timed out.  You should be able to login to multiple requests and one-by-one the tests should resume.