Solution Type Problem Resolution Sure Solution 1950792.1 : SL3000/SL8500 - Terminators Received With Connectors Not Seated Correctly
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL3000 Modular Library System - Version All Versions and laterSun StorageTek SL8500 Modular Library System - Version All Versions and later Information in this document applies to any platform. SymptomsTerminators Received with Connectors not Seated Correctly. This can result in robot resets and other errors either immediately or years later as vibration and oxidation cause the marginal electrical connection to ultimately fail. CauseManufacturing issue. SolutionALWAYS check for proper insertion of BOTH Sta-Kon connectors between the terminator circuit-board and the white plastic splice shell during installations. Also check when trying to diagnose high rail network errors. Attachments This solution has no attachment |
||||||||||||||||
|