![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1948823.1 : SL8500 - Expansion Module Cables Wrong, PN313890302
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL8500 Modular Library System - Version All Versions and laterInformation in this document applies to any platform. We have identified bad cables in the field that ship with new SL8500 installs that contain the SEM SymptomsSL8500 - Expansion Module Cables Wrong, PN313890302. P/N-313890302, CBL ASSY,JMPR,AC PWR-FRT,EF The P728 and J728 white connectors were reversed and attached to the wrong set of pins. As a result, the cable cannot be connected at the CIM and RIM. ChangesNew installation of SL8500 library. CauseManufacturing assembly issue. SolutionThe correct connector pin assignment would have been: P728; male connector with female pins J728; female mating connector with male pins
Incorrect connector pin assignment: P728; male connector with male pins J728; female mating connector with female pins
Interim Solution: One local site reversed the connectors to address the issue. The cable manufacturer is in process of re-manufacturing the cables correctly. Replacement cables should be ready by late December 2014. Note: Update as of 2/2015 replacement cables are now available from quality engineering in Colorado. Please escalate any request for replacement cables via email to the Colorado SL8500 support team; bruce.mcdonald@oracle.com or saleem.ahmed@oracle.com. Will need shipping address, contact name, and contact telephone number along with quantity required.
Attachments This solution has no attachment |
||||||||||||||||||
|