![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1948293.1 : SL150 - Library Does Not Power On
At installation library was found to be dead with slow flashing LED on both power supplies in base and no light on the power button. In this Document
Created from <SR 3-9876963941> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions and laterInformation in this document applies to any platform. SL150 2.25 SymptomsLibrary uncommunicative. Nothing on the screen. Power button is not lit. No reaction to power on reset other than slow flashing on LEDs on PSUs in base. Factory reset obviously was not an option as there was no power. ChangesNew installation. CauseFailed robot module SolutionThe PSUs were replaced and the front panel (as there was seemingly no power to the power on button) but this did not work. Reseated all modules to no avail. Replaced robot module and the PSUs flashed twice and the library came up normally. References<NOTE:1473799.1> - SL150 - How to do a Factory Reset on the StorageTek SL150 Modular Tape Library<NOTE:1517227.1> - SL150 - Library Does Not Power On After Replacement of Robotic Module <NOTE:1559312.1> - SL150 - How to Power Library On/Off Attachments This solution has no attachment |
||||||||||||||||||||
|