Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1947834.1
Update Date:2016-09-06
Keywords:

Solution Type  Problem Resolution Sure

Solution  1947834.1 :   REST Application Server (RAS) Out of Service (OOS) On Subscriber Profile Repository (SPR) Slot 3  


Related Items
  • Oracle Communications Subscriber Data Management (SDM)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Broadband Network Solutions>SN-SND: Tekelec SDM
  •  


RAS goes OOS when more than 50 TPS are received.

In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-9467204281>

Applies to:

Oracle Communications Subscriber Data Management (SDM) - Version SDM 9.0 and later
Information in this document applies to any platform.
BlueVersion version less than 9.0.x

Symptoms

Core file generated:

Core was generated by `ras -orl /NodeManager3/RasServer -i 3 -name RasServer -id 1 -s 15'.
Program terminated with signal 11, Segmentation fault.

#7  0xf7e9525e in blueslice::http::Daemon::prv_run (this=0x87fb828)
    at Daemon.cpp:478
        ms = 20
        max = 32
        to = 20
        rasTimeout = 64

RAS goes OOS.

Changes

 No changes

Cause

Provisioning is unable to control the amount of Transactions Per Second (TPS) send to SPR.

Solution

Upgrade to BlueVersion 9.3.1 where 100 TPS as maximum are supported.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.