![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1944793.1 : Fujitsu M10-1/M10-4/M10-4S XCP2230: Hypervisor Regression Causing Guest Domains not to Boot
In this Document
Applies to:Fujitsu M10-1 - Version All Versions and laterFujitsu M10-4 - Version All Versions and later Fujitsu M10-4S - Version All Versions and later Information in this document applies to any platform. SymptomsGuest domain fails to boot. <Need some examples of the issue > ChangesNewly installed system with XCP2230. CauseWhen Live Migration is performed, Hypervisor does not clear VCPU state appropriately. The VCPUs on source system of Live Migration keeps inappropriate state and eventually the VCPUs do not receive any interrupts. If a new guest domain is created on the VCPUs, the guest domain fails to boot. To verify you are running on XCP2230 run the "version -c xcp" command. XSCF> version -c xcp
BB#00-XSCF#0 (Master) XCP0 (Reserve): 2230 XCP1 (Current): 2230 This issue only affects XCP2230 and is fixed in XCP2231 and above. SolutionPlease upgrade the XCP to XCP2231 or later. XCP information is available in document 1554086.1. References<NOTE:1554086.1> - Fujitsu M10-1/M10-4/M10-4S XSCF Control Package (XCP) Firmware Image Software Version Matrix InformationAttachments This solution has no attachment |
||||||||||||||||||||
|