![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1944729.1 : Pillar Axiom: AxiomCLI utility for Windows does not work on Axiom release v5.4.15 and v5.4.16
In this Document
Created from <SR 3-9809125111> Applies to:Pillar Axiom 500 Storage System - Version Not Applicable to Not Applicable [Release N/A]Pillar Axiom 600 Storage System - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. SymptomsOn Pillar Axiom release v5.4.15 and v5.4.16 the Windows AxiomCLI utility stops working producing the following compilation error message when logging into the Axiom: Can't locate Params/Validate.pm in @INC
BEGIN failed--compilation aborted at Log/Dispatch/Output.pm line 13. Compilation failed in require at Log/Dispatch/FileRotate.pm line 10. BEGIN failed--compilation aborted at Log/Dispatch/FileRotate.pm line 10. Compilation failed in require at AXCLILogger.pm line 40. BEGIN failed--compilation aborted at AXCLILogger.pm line 40. Compilation failed in require at ErrorHandler.pm line 35. BEGIN failed--compilation aborted at ErrorHandler.pm line 35. Compilation failed in require at script/axiomcli.pl line 31. BEGIN failed--compilation aborted at script/axiomcli.pl line 31. at -e line 968
CauseThe issue is caused from a missing package at the time the AxiomCLI utility was built. SolutionThe issue has been fixed in release v5.4.17. Please upgrade the Axiom to obtain the software fix. The alternative solution is to use the version of the AxiomCli utility for Windows v5.4.14 attached to the document below. References<BUG:20016970> - AXIOMCLI ON V05.04.15 SEEMS TO HAVE A PACKAGING ISSUEAttachments This solution has no attachment |
||||||||||||||||||
|