Asset ID: |
1-72-1943537.1 |
Update Date: | 2014-11-16 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1943537.1
:
INFINICHECK: CRITICAL PERFORMANCE RUN HAD TIMEOUTS!
Related Categories |
- PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Infiniband
|
running infinicheck yields error:
[CRITICAL].........CRITICAL Performance Run had timeouts!
In this Document
Created from <SR 3-9660490007>
Applies to:
Exadata X3-2 Eighth Rack - Version All Versions and later
Information in this document applies to any platform.
Symptoms
running infinicheck command to validate a PSR document and I have alerts in the output report:
[root@dex1db01ibdiagtools]#./infinicheck -g <IP_address>,<IP_address> -c
<IP_address>,<IP_address>,<IP_address>
INFINICHECK
[Network Connectivity, Configuration and Performance]
[Version IBD VER 2.c 11.2.3.2.1 130109]
[ ... ]
#### PERFORMANCE TESTS ####
[(1) Storage Cell to Compute Node]
(135 seconds approx)
[CRITICAL].........CRITICAL Performance Run had timeouts!
[(2) Every COMPUTE NODE to another COMPUTE NODE]
(75 seconds approx)
[SUCCESS]..............Results OK
[(3) Every COMPUTE NODE to ALL STORAGE CELLS]
(looking for SymbolErrors)
(195 seconds approx)
[CRITICAL].........CRITICAL Performance Run had timeouts!
[SUCCESS]....... No port errors found
Infinicheck failures reported.. please check log files
Recommendation
===
Cause
the error message contains no clue as to the source of the problem, which was determined to be related to the ssh keys on some of the hosts.
Solution
regenerate the keys and setup user equivalence and then run infinicheck: The issue was solved by regenerating the [ ssh ] keys.
References
<BUG:19723222> - INFINICHECK: CRITICAL PERFORMANCE RUN HAD TIMEOUTS!
Attachments
This solution has no attachment