![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1943342.1 : Tracking Area Update (TAU) Complete Procedure xDR are Missing in S1 MME session
In this Document
Created from <SR 3-9301358951> Applies to:Oracle Communications Performance Intelligence Center (PIC) Software - Version 9.0.3 to 10.1.0 [Release 9.0 to 10.0]Information in this document applies to any platform. SymptomsNo "TAU complete" messages found in S1 MME session. The only messages decoded for Tracking area update are "request" and "reject". CauseRun pcap capture at pmf level in order to verify that message are present on monitored network. Messages are present in pcap capture. Detected on with WireShark with the following filter : "nas_eps.nas_msg_emm_type == 74" Messages are present in ProTrace but the L3ProcedureCode is not correctly set and is equal to "null". SolutionBugDB:19464165 fixed on 10.1 Attachments This solution has no attachment |
||||||||||||||||
|