Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1943342.1
Update Date:2017-02-15
Keywords:

Solution Type  Problem Resolution Sure

Solution  1943342.1 :   Tracking Area Update (TAU) Complete Procedure xDR are Missing in S1 MME session  


Related Items
  • Oracle Communications Performance Intelligence Center (PIC) Software
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-9301358951>

Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 9.0.3 to 10.1.0 [Release 9.0 to 10.0]
Information in this document applies to any platform.

Symptoms

No "TAU complete" messages found in S1 MME session.

The only messages decoded for Tracking area update are "request" and "reject".

Cause

Run pcap capture at pmf level in order to verify that message are present on monitored network.

Messages are present in pcap capture. Detected on with WireShark with the following filter : "nas_eps.nas_msg_emm_type == 74"

Messages are present in ProTrace but the L3ProcedureCode is not correctly set and is equal to "null".

Solution

BugDB:19464165 fixed on 10.1
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback