![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1941237.1 : SL8500 - All Components Except Drives Went Inoperative After Access Door Opened With Service Mode
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL8500 Modular Library System - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. SSD = Service Safety Door SymptomsConfirmed problem using left and right SSD. All components except drive all went to inop after access door open. Actuated LEFT SSD and door open ChangesN/A CauseAll SSD sensors have been properly stated after actuating SSD like below on NBN LED states. Internal cable 3138917xx connector P501 pin5 red/white "service mode override" signal was not properly seated to HBN.
SolutionTemporary repaired at site and cable 313891703 is replaced. References<NOTE:1019933.1> - SL8500 - Drive and Rail Power Supply Troubleshooting Information<NOTE:1020745.1> - SL8500 - Problem With Initialization of New Installed Service Safety Door (SSD) Attachments This solution has no attachment |
||||||||||||||||||||
|