![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1939749.1 : SL8500 - SDP Generated 1304 Elevator Hardware Failure
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsSDP Alert received with 1304 Elevator Hardware failure. CauseElevator Hardware mechanical issue SolutionExamine the Elevator/Carriage/Array assembly. Check for worn belt, delaminating carriage rollers or tube damage. 1. Common failure is for the elevator is 4 cell array becomes fractured or separated at its mount point. This results in intermittent failures if fractured or a dead elevator if the array falls off. In either case there is a spare, unused, 4 cell array that can be used from the turntable in the bottom of the elevator tower in an emergency. How to Diagnose Elevator Problems on SL8500 Library:ATR:1391024.1:2 (Doc ID 1391024.1)