Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1939749.1
Update Date:2017-09-25
Keywords:

Solution Type  Problem Resolution Sure

Solution  1939749.1 :   SL8500 - SDP Generated 1304 Elevator Hardware Failure  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Automation purposes

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

 SDP Alert received with 1304 Elevator Hardware failure.

Cause

 Elevator Hardware mechanical issue

Solution

Examine the Elevator/Carriage/Array assembly.  Check for worn belt, delaminating carriage rollers or tube damage.

1. Common failure is for the elevator is 4 cell array becomes fractured or separated at its mount point. This results in intermittent failures if fractured or a dead elevator if the array falls off. In either case there is a spare, unused, 4 cell array that can be used from the turntable in the bottom of the elevator tower in an emergency.

2. Elevator failures can also be caused by a un-cleared reserve from some other robotic failure in the library. Rebooting the elevators from the SLConsole should be attempted to clear the reserve. In the event that the SLC cannot force the boot due to the reserve, the elevators and caps can be rebooted by removing the 2 48 volt supplies for 10 seconds. The original robotic failure needs to be investigated.

3. If rebooting the elevators, open an SLConsole Monitor "Error, Warn, Info" window and observe both the physical movements of the mechanisms and the output of the monitor window. Together this will provide detailed information on what is happening.

How to Diagnose Elevator Problems on SL8500 Library:ATR:1391024.1:2 (Doc ID 1391024.1)

 