Solution Type  Problem Resolution Sure

Solution  1937887.1 :   E5-MASP Card is Faulty  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-9511280231>

Applies to:

Oracle Communications EAGLE (Hardware) - Version EAGLE 44.x and later
Information in this document applies to any platform.

Symptoms

E5-MASP card does not come up in-service active.

Cause

The card is faulty.

Solution

The spare card was used to replace the suspected faulty one.

Please also refer to the Eagle documentation in the Maintenance Manual to see how to replace an E5-MASP card : Doc 910-6282-001 for Eagle R44 :

E5-MASP Card Replacement
This procedure is to replace an E5-MASP card. Before the E5-MASP is replaced, it must be verified
that is the standby MASP.
The E5-MASP (made up of the E5-MCAP and E5-TDM cards) contains the removable USB drive, the
fixed disk drive, the terminal processor for the 16 serial I/O ports, and an interface to the maintenance
disk and alarm (E5-MDAL) card.
1. Before beginning this procedure, make sure there is a copy of the current release GPLs on a
removable USB cartridge on-hand.
2. If the active E5-MASP card fails, the EAGLE 5 ISS automatically switches activity to the standby
MASP.

....